Activating new 2LIS extractor (previously inactive) and delta queue
Hi all,i have a question about activating 2LIS_11_VASCL (currently inactive): I have others active extractors in the same application 11, if I enhance and activate 2LIS_11_VASCL i need to clear the...
View ArticleRe: Activating new 2LIS extractor (previously inactive) and delta queue
Hi, if you need to clear delta queues means you need to load all delta data from source to bw and keep all queues as 0. at RSA7 check your data source total column need to have 0. for safe side we need...
View ArticleRe: Activating new 2LIS extractor (previously inactive) and delta queue
Hi,i don't need to load any delta for the new extractor right now (it will be loaded via setup table for the moment, to test the data flow).I only need to trasport the structure and activate it without...
View ArticleRe: Activating new 2LIS extractor (previously inactive) and delta queue
Hi, Delta queue doesn't impact in your case. Delta queue(RSA7) is respective of data source not application wise. Assuming as you want transport your new data source of application 11.Then you can...
View ArticleTransfer (Idocs and TRFC): Errors occured
Dear All, data extraction from R/3 into BI is working for small number of records. for huge number of records it ends with error,i have adjusted info package setting DataS. Default Data Transfer but...
View ArticleRe: Transfer (Idocs and TRFC): Errors occured
Hi, at ECC side, SM37, have you seen your job logs?please check your job log at source side SM37. is this error is coming for only one load or all loads?is this new or fresh system? Before this load...
View ArticleRe: Transfer (Idocs and TRFC): Errors occured
Dear Ramanjaneyulu, thank you for your replay, it is not new landscape. on ECC side it SM37 the process ends with success. & every thing is working. i can extract small number of records the error...
View ArticleRe: Transfer (Idocs and TRFC): Errors occured
is this happening for only data source? is it full load?in such case try to use selections at info pack and load data into bw. at BW side ,have you doing house keeping activities? Even you need to...
View ArticleDelta not supporting for enhanced fields.
Hi All,In one of the standard table ie) VBAK, 2 news fields are added in the standard table. Right now we are using 2LIS_11_VAITM data source to pick data to BW. In TCODE LBWE, for the data source...
View ArticleRe: Delta not supporting for enhanced fields.
Hi, Standard data source works delta functionality on its own.About them you can check at RSA2 and see delta details about it. If enhanced field was changed then delta won't pull those changes.Even we...
View ArticleRe: Delta not supporting for enhanced fields.
Hi Jalina, Have you written the user exit code for newly added fields? If not I suggest you write proper code in user exit to populate the custom fields.As far as making them delta relevant, it is...
View ArticleRe: Transfer (Idocs and TRFC): Errors occured
Hi demise,Is your datasource a custom datasource? If yes, is there any dump raised in SAP for large no. of records, please check ST22 after you run your infopackage for large no. of records.Can you try...
View ArticleRe: error Message no. RSAR245
I had the same issue and solved it the following way: On the InfoSource maintenance screen click on "Propose Transfer Rules" button on the right of Transfer Rules -> Communication str./Transfer rules
View ArticleRe: Transfer (Idocs and TRFC): Errors occured
Dear Amit, yes the data source is custom & we are using selection at infopackage. the data source was working in the last weeks. previously we can process one month data. but right now it is not...
View ArticleRe: Unable to Generate Transfer Structure for Totals Table
Hi Eric, Access keys are passed by Basis team. Please click on Information on your screen shot and pass it to basis team. They will be able to help you out with the installation no. and object its...
View ArticleRe: Transfer (Idocs and TRFC): Errors occured
Okay then I would think that there is some cofiguration issue related to communication between two system. Can you check below: 1. SM59 - RFC connections are wroking fine?2. Any stuck Idoc or failed...
View ArticleVistex standard extractor fields
Hi Experts, Please kindly request your help to find documentation with the list of fields for the Vistex standard extractors. I have checked the vistex help page and also found some white papers, but...
View ArticleNo Data in Field Scrap quantity (AMGLG) after Append DataSource...
Hi experts, we enhanced the BI Content standard DataSource 2LIS_04_P_COMP "Component View from PP/PP-PI" with the field AMGLG (Scrap quantity) per maintenance of the relevant extract structure...
View ArticleRe: No Data in Field Scrap quantity (AMGLG) after Append DataSource...
Hi Michael, Have you uncheked the 'Hide Field' and 'Field Only Known at Exit' in RSA6 after you have enhanced the datasource for field in LBWE?These should be unchecked else data will not be populated...
View ArticleRe: No Data in Field Scrap quantity (AMGLG) after Append DataSource...
Hi Amit, yes, these basic settings were already made. RSA6: Regards,Michael
View Article