Re: How to decide the Update methods in LO extractions

Thanks For the response SVU.  Regards,Bala

View Article


Re: 0PS_10 datasource taking long time to extract data into BW

Hi Bhavin, I tried to to put routine on info-package as a Pseudo Delta, but it did not work the reason is in my view selection is not working therefore Pseudo Delta or any routine on it will not work,...

View Article


Re: 0PS_10 datasource taking long time to extract data into BW

Hello Zeeshan, The DataSource 0PS_10 was not designed load data into the PSA. It was actually designed for direct data access at BW query execution time. I recommend you use BW queries 0PS_M10_Q0001,...

View Article

Re: 0PS_10 datasource taking long time to extract data into BW

Hi Roger, thanks for your response.The reason i would like to load data into PSA is we are using this datasource data for BPC so its important for us to extract data into BW, at the moment i am trying...

View Article

Re: upgrate BI content 7.03 to BI content 7.07

See this document for your requirement, Current BI Content Releases in Maintenance and/or Development Thanks,Bhavin vyas

View Article


Re: 0PS_10 datasource taking long time to extract data into BW

Hi Zeeshan, The function module PS_CALL_PSJ is the central logic block of this DataSource, and its performance heavily depends on the selection criteria. Therefore, maybe you could run multiple...

View Article

Re: 0PS_10 datasource taking long time to extract data into BW

Hi Zeeshan, I think selections would work on these fields only. Project Defintion, WBS element, network, activity, material, and sales document as selection criteria. Read this help page, Project...

View Article

Re-Init LIS-Extractors connected to multiple target systems

Hello all, I have the following questions regarding LIS-Delta Extraction and would be glad to get your opinion on this. Thanks a lot in advance! Kind regards,Sven ------------- 1) I want to use Early...

View Article


Re: Re-Init LIS-Extractors connected to multiple target systems

Hi Sven, Safer side, if client accepts, better to lock source system and do the extraction until you set up delta. 1. Yes and those will be captured in your delta because of early delta init. 2.1....

View Article


Re: Re-Init LIS-Extractors connected to multiple target systems

Hello Chowtharythank you for your answer. I really want to avoid stopping document posts. According to your answer for question 1, new and changed documents are still posted to the queue for the...