Re: Precautions while Transporting data sources.

Hi, NO and never delete it.Clear means you need to load all queus data into bw. To clear LBWQ - you need to schedule V3 job and later trigger your delta info pack. Thanks

View Article


Re: Precautions while Transporting data sources.

Alternatively you can clear the Extraction queue (LBWQ) with the help of program as well. Go to SE38 and enter RMBWV3* * followed by application number.In your case it will be 03 and 05. Hope this...

View Article


Re: Datasource based on BKPF table

HI Vikrant, Cross check the docnos b/w BSEG and FAGLFLEXA tables. There is standard datasource 0FI_GL_14 on FAGLFLEXA, you can use the same instead of BSEG.  Regards,PRK.

View Article

Re: extraction issue after System Refresh

Hi Nilesh, Please ensure that the BDLS in the target system has been run properly. Also please check in SE16 whether the Logical System name entry has changed or not for the corresponding table.

View Article

Re: extraction issue after System Refresh

Hi The main purpose of BDLS run is to change Logical system name.After BDLS check RFC connection,Partner Profile and the most important the  table RSLOGSYSDEST.Here see the entries of Logsys and...

View Article


Re: extraction issue after System Refresh

thanks Biplav - issue fixed by activating transfer rules

View Article

Re: BW Data sources - Source Tables Information ?

Perfect answer, I tried , it works. It acutally give you the SQL statement, which reveal more details. Thanks a million!!

View Article

Re: Business content datasource configuration for EHSM

if you are createing generic datasources, you need to at least post the screen shot of you datasourse using tcode RSA2,

View Article


Image may be NSFW.
Clik here to view.

Re: 3FI_GL_XX_SI: Clearing date is not properly updated in delta mode.

Hi, "Change document" is set:  Can you described in detail what I have to do here: Later try to set delta pointer at info  pack and do changes.try to load data. I'm no expert and I will not go wrong.

View Article


Re: 3FI_GL_XX_SI: Clearing date is not properly updated in delta mode.

You set above settings or previously it was set.if it was set then not possible. if you set now then you need to reinit your delta at info pack.mean delete the delta pointer and do the reinit.later...

View Article

Re: 3FI_GL_XX_SI: Clearing date is not properly updated in delta mode.

It was already set.

View Article

Re: 3FI_GL_XX_SI: Clearing date is not properly updated in delta mode.

Then no use. please raise to SAP.

View Article

Image may be NSFW.
Clik here to view.

Re: 3FI_GL_XX_SI: Clearing date is not properly updated in delta mode.

Hi,I haven't seen this problem in a system I work on !!!Leszek

View Article


Image may be NSFW.
Clik here to view.

Re: 3FI_GL_XX_SI: Clearing date is not properly updated in delta mode.

Very confusing. Same settings within our system but issue still exists:  Are there any other setting to check? E.g. within TCODE " SPRO" (IMG)?

View Article

Runtime error while compressing 0IC_C03 with 2LIS_03_BF

Hello Experts, We are facing a runtime while doing a compression on 0IC_C03 with BF extractor. We have checked all the threads and Unfortunately could not find any luck in solving the issues. It ends...

View Article


Re: overflow error while loading from flat file to PSA

Hi, Even I am facing the similar problem, what is the logic behind calculating the Field length and precision ?

View Article

Re: Runtime error while compressing 0IC_C03 with 2LIS_03_BF

Hi Sreenivas,  Look if the SAP Note 1978153 can help you... Best Regards, Enio Terra

View Article


Image may be NSFW.
Clik here to view.

Re: 3FI_GL_XX_SI: Clearing date is not properly updated in delta mode.

Hi, So the problem is that one (exactly one) field (AUGDT) is not updated in delta, in all data flows (FIGL AP AR).    Yes ?   Changes in documents can be checked in: S_ALR_87012293 or FB03 like...

View Article

Re: SAP BW Source System Port Descript RSAR 669, RSAR 8, RSAR 371, RSAR 374,...

Hi, Take basis team help and ask them to see the WE05/20.partner profile need to be active. Ask basis team to maintain proper logical mappings between ECC and BW.table - RSLOGSYSMAP(table need to have...

View Article

Time out Issues with FM Based Extractor

Hi All,Requirement is to get the request details from more than one table and join conditions are not 1-1. It requires some text to be appended to join another table and need to lookup log tables to...

View Article