Hi Thilini,

 

Few points to be looked into,

In ECC-QA,

  • some of the datasources would have got deactivated or overwritten or got deleted.So in few cases you may have to reimport the Datasource,so please check betweeen PRD and QA and then do the necessary activities.
  • For LO Datasource,clear the LBWQ.
  • in RSA7-some of them would have become inactive,So in BW we have to delete the init and then do a Reinit.

In BW-QA.

  • Check if the RFC is working fine.
  • Check if the Source system is working fine by going to source system (Pointing) -Check/Activate.
  • Check if the Datasources are inactive by replicating,if they are inactive then activate them.
  • Delete the init from Infopack and do a reinit,such that the DS is active in RSA7 (ECC-QA).
  • You may loose the Delta track as you are doing init,Data to DSO/Cube/FLows/Looksups may have to be reloaded.Else Testing in QA will become a challenge.